{"id":94845,"date":"2024-01-11T12:52:59","date_gmt":"2024-01-11T12:52:59","guid":{"rendered":"https:\/\/bakarna-lda.com\/?post_type=product&#038;p=94845"},"modified":"2024-01-11T12:52:59","modified_gmt":"2024-01-11T12:52:59","slug":"apsm-self-priming-peripheral-pump","status":"publish","type":"product","link":"https:\/\/bakarna-lda.com\/index.php\/product\/apsm-self-priming-peripheral-pump\/","title":{"rendered":"APSm Self-Priming Peripheral Pump"},"content":{"rendered":"<p><strong>Application<\/strong><br \/>\n&#8211; Can be used to transfer clean water or other liquids similar to water in physical and chemical properties.<br \/>\n&#8211; Suitable for lifting water from the well, sprinkling irrigation in garden, pressure boosting of running water, and supporting equipment etc.<\/p>\n<p><strong>APSm Self-Priming Peripheral Pump Features<\/strong><br \/>\n&#8211; LEO&#8217;s APSm Self-Priming Peripheral Pump&#8217;s cast iron pump body and support all underwent a special anti-rust treatment.<br \/>\n&#8211; Anti-block system is introduced for APSm Self-Priming Peripheral Pump&#8217;s impeller;<br \/>\n&#8211; Brass impeller<br \/>\n&#8211; AISI 304 shaft<br \/>\n&#8211; Max. liquid temperature: +40\u2103<br \/>\n&#8211; Max. suction: +9m<br \/>\n&#8211; self-priming<\/p>\n<p><strong>APSm Self-Priming Peripheral Pump Motor Features<\/strong><br \/>\n&#8211; Copper winding<br \/>\n&#8211; Built-in thermal protector for single phase motor<br \/>\n&#8211; F grade insulation is well met for our self-priming pumps.<br \/>\n&#8211; Protection class: IPX4<br \/>\n&#8211; Max. ambient temperature: +40\u2103<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-94847 size-full\" src=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump.jpg\" alt=\"\" width=\"557\" height=\"300\" srcset=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump.jpg 557w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump-300x162.jpg 300w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump-18x10.jpg 18w\" sizes=\"(max-width: 557px) 100vw, 557px\" \/><\/p>\n<p><strong>Technical Data of APSm Self-Priming Peripheral Pump<\/strong><\/p>\n<div class=\"table-responsive\">\n<table class=\"table table-hover ke-zeroborder\">\n<tbody>\n<tr>\n<td colspan=\"2\">MODEL<\/td>\n<td colspan=\"2\">POWER<\/td>\n<td>Q\uff08m3\/h\uff09<\/td>\n<td>0<\/td>\n<td>0.3<\/td>\n<td>0.6<\/td>\n<td>0.9<\/td>\n<td>1.2<\/td>\n<td>1.5<\/td>\n<td>1.8<\/td>\n<td>2.1<\/td>\n<td>2.4<\/td>\n<td>3<\/td>\n<td>3.3<\/td>\n<td>3.6<\/td>\n<td>4.2<\/td>\n<\/tr>\n<tr>\n<td>Single Phase<\/td>\n<td>Three Phase<\/td>\n<td>(KW)<\/td>\n<td>(HP)<\/td>\n<td>Q(L\/min)<\/td>\n<td>0<\/td>\n<td>5<\/td>\n<td>10<\/td>\n<td>15<\/td>\n<td>20<\/td>\n<td>25<\/td>\n<td>30<\/td>\n<td>35<\/td>\n<td>40<\/td>\n<td>50<\/td>\n<td>55<\/td>\n<td>60<\/td>\n<td>70<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.leo-pumps.com\/1-1-2-1-self-priming-peripheral-pump.html#\"><u class=\"inquiry\">APSm37\u00a0<\/u><\/a><\/td>\n<td>\/<\/td>\n<td>0.37<\/td>\n<td>0.5<\/td>\n<td rowspan=\"4\">H(m)<\/td>\n<td>40<\/td>\n<td>35<\/td>\n<td>28<\/td>\n<td>22<\/td>\n<td>18<\/td>\n<td>12<\/td>\n<td>5<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.leo-pumps.com\/1-1-2-1-self-priming-peripheral-pump.html#\"><u class=\"inquiry\">APSm60<\/u><\/a><\/td>\n<td>\/<\/td>\n<td>0.6<\/td>\n<td>0.8<\/td>\n<td>45<\/td>\n<td>40<\/td>\n<td>32<\/td>\n<td>28<\/td>\n<td>22<\/td>\n<td>18<\/td>\n<td>12<\/td>\n<td>8<\/td>\n<td>5<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.leo-pumps.com\/1-1-2-1-self-priming-peripheral-pump.html#\"><u class=\"inquiry\">APSm75<\/u><\/a><\/td>\n<td>\/<\/td>\n<td>0.75<\/td>\n<td>1<\/td>\n<td>55<\/td>\n<td>50<\/td>\n<td>42<\/td>\n<td>38<\/td>\n<td>32<\/td>\n<td>28<\/td>\n<td>22<\/td>\n<td>18<\/td>\n<td>12<\/td>\n<td>5<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<td>\/<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.leo-pumps.com\/1-1-2-1-self-priming-peripheral-pump.html#\"><u class=\"inquiry\">APSm110<\/u><\/a><\/td>\n<td><a href=\"http:\/\/www.leo-pumps.com\/1-1-2-1-self-priming-peripheral-pump.html#\"><u class=\"inquiry\">APS110<\/u><\/a><\/td>\n<td>1.1<\/td>\n<td>1.5<\/td>\n<td>65<\/td>\n<td>60<\/td>\n<td>55<\/td>\n<td>50<\/td>\n<td>45<\/td>\n<td>40<\/td>\n<td>35<\/td>\n<td>30<\/td>\n<td>25<\/td>\n<td>20<\/td>\n<td>15<\/td>\n<td>10<\/td>\n<td>5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"clear\"><\/div>\n<p><strong>APSm Self-Priming Peripheral Pump Hydraulic Performance Curve<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-94848 size-full\" src=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump_02.jpg\" alt=\"\" width=\"600\" height=\"335\" srcset=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump_02.jpg 600w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump_02-300x168.jpg 300w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump_02-18x10.jpg 18w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><strong>Material Table for APSm Self-Priming Peripheral Pump<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-94849 size-full\" src=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump_03.jpg\" alt=\"\" width=\"600\" height=\"466\" srcset=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump_03.jpg 600w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump_03-300x233.jpg 300w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/1-1-2-1-self-priming-peripheral-pump_03-15x12.jpg 15w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<div class=\"clear\">\n<table class=\"table table-hover ke-zeroborder\">\n<tbody>\n<tr>\n<td>No.<\/td>\n<td>Part<\/td>\n<td>Material<\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>Screw<\/td>\n<td>steel<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Pump Body<\/td>\n<td>HT200<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Impeller<\/td>\n<td>Brass<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Mechanical seal<\/td>\n<td>carbon\/ceramic<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>O-ring<\/td>\n<td>NBR<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Support<\/td>\n<td>HT200<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Bearing<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Rotor<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>Fan cover<\/td>\n<td>PP<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>Fan<\/td>\n<td>PP<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>Rear cover<\/td>\n<td>ZL102<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>Capacitor<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>Terminal box<\/td>\n<td>ABS<\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>Stator<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>Terminal board<\/td>\n<td>PC<\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>Non-return Valve<\/td>\n<td>NBR<\/td>\n<\/tr>\n<tr>\n<td>17<\/td>\n<td>Connector<\/td>\n<td>HT200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Application &#8211; Can be used to transfer clean water or other liquids similar to water in physical and chemical properties. &#8211; Suitable for lifting water from the well, sprinkling irrigation in garden, pressure boosting of running water, and supporting equipment etc. APSm Self-Priming Peripheral Pump Features &#8211; LEO&#8217;s APSm Self-Priming Peripheral Pump&#8217;s cast iron pump&hellip;<\/p>\n","protected":false},"featured_media":94846,"comment_status":"open","ping_status":"closed","template":"","meta":{"_eb_attr":""},"product_brand":[],"product_cat":[274,272,273],"product_tag":[],"class_list":{"0":"post-94845","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-domestic-pump","7":"product_cat-peripheral-pumps","8":"product_cat-pumping","9":"description-off","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product\/94845","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/comments?post=94845"}],"version-history":[{"count":1,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product\/94845\/revisions"}],"predecessor-version":[{"id":94850,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product\/94845\/revisions\/94850"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/media\/94846"}],"wp:attachment":[{"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/media?parent=94845"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=94845"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=94845"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=94845"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}