{"id":94620,"date":"2024-01-10T19:04:58","date_gmt":"2024-01-10T19:04:58","guid":{"rendered":"https:\/\/bakarna-lda.com\/?post_type=product&#038;p=94620"},"modified":"2024-01-10T19:05:53","modified_gmt":"2024-01-10T19:05:53","slug":"arp-circulation-pump","status":"publish","type":"product","link":"https:\/\/bakarna-lda.com\/index.php\/product\/arp-circulation-pump\/","title":{"rendered":"ARP Circulation Pump"},"content":{"rendered":"<p><strong>Application<\/strong><br \/>\n-The ARP circulation pump is used for transferring clean water or other liquids similar to water in physical and chemical properties<br \/>\n-Heating systems with constant or variable flows<br \/>\n-Heating systems with variable flow-pipe temperature<br \/>\n-Heating systems where night setback is desired<br \/>\n-Heating systems where the differential pressure of the pump is too high during periods of reduced flow demand<br \/>\n-Heating systems that require a fully automatic adjustment of the performance to flow demands<br \/>\n-Pressure boosting of water heaters<br \/>\n-Circulation and pressure boosting of domestic water<\/p>\n<p><strong>Pump<\/strong><br \/>\nCompact design with a perfectly integrated control unit<br \/>\nRust resistant cast iron pump body<br \/>\nNoryl impeller with heat resistance up to 150\u00b0C<br \/>\n99% alumina ceramic shaft<br \/>\nLiquid temperature: 2\u00b0C to 110\u00b0C<\/p>\n<p><strong>Motor<\/strong><br \/>\nInsulation class: H<br \/>\nProtection class: IP42<br \/>\n99% alumina ceramic bearing<br \/>\nCopper winding<br \/>\nPower \/frequency (V\/Hz): 220-240\/50<br \/>\nEEI: \u2264 0.23, which complies with the European Directives<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-94622 size-full\" src=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-arp-circulation-pump-new-01.jpg\" alt=\"\" width=\"948\" height=\"344\" srcset=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-arp-circulation-pump-new-01.jpg 948w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-arp-circulation-pump-new-01-300x109.jpg 300w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-arp-circulation-pump-new-01-768x279.jpg 768w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-arp-circulation-pump-new-01-18x7.jpg 18w\" sizes=\"(max-width: 948px) 100vw, 948px\" \/><\/p>\n<p><strong>ARP Circulation Pump Function Introduction<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-94623 size-full\" src=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-02.jpg\" alt=\"\" width=\"1109\" height=\"380\" srcset=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-02.jpg 1109w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-02-1000x343.jpg 1000w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-02-300x103.jpg 300w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-02-1024x351.jpg 1024w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-02-768x263.jpg 768w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-02-18x6.jpg 18w\" sizes=\"(max-width: 1109px) 100vw, 1109px\" \/><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-94624 size-full\" src=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-03.jpg\" alt=\"\" width=\"1096\" height=\"470\" srcset=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-03.jpg 1096w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-03-1000x429.jpg 1000w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-03-300x129.jpg 300w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-03-1024x439.jpg 1024w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-03-768x329.jpg 768w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-03-18x8.jpg 18w\" sizes=\"(max-width: 1096px) 100vw, 1096px\" \/><\/p>\n<table class=\"table table-hover ke-zeroborder\">\n<tbody>\n<tr>\n<td><strong>Mode<\/strong><\/td>\n<td><strong>Pump Feature<\/strong><\/td>\n<td><strong>Function<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Auto<\/td>\n<td>Max.to min. proportional pressure curve<\/td>\n<td>The automatic adaptation function allows the pump to control the performance to within a defined performance range (i.e. adjusting the pump performance to the system size and the variations in load over time). In this mode, the pump is set to proportional-pressure control<\/td>\n<\/tr>\n<tr>\n<td>PP1<\/td>\n<td>Min. Proportion pressure curve<\/td>\n<td>The pump duty point will move up or down on the lowest proportional pressure curve, depending on the heat demands in the system. The pressure is reduced when the heat demand falls, and increases when the demand rises<\/td>\n<\/tr>\n<tr>\n<td>PP2<\/td>\n<td>Max. Proportion pressure curve<\/td>\n<td>The duty point of the pump will move up or down on the highest proportional pressure curve, depending on the heating demand in the system. The pressure is reduced when the heat demand falls, and increases when demand rises<\/td>\n<\/tr>\n<tr>\n<td>CP1<\/td>\n<td>Max. constant pressure curve<\/td>\n<td>The duty point of the pump will move out or in on the highest constant-pressure curve, depending on the heat demand in the system. The pressure is kept constant, regardless of the heat demand.<\/td>\n<\/tr>\n<tr>\n<td>CP2<\/td>\n<td>Min. constant pressure curve<\/td>\n<td>The duty point of the pump will move out or in on the highest constant-pressure curve, depending on the heat demand in the system. The pressure is kept constant, regardless of the heat demand.<\/td>\n<\/tr>\n<tr>\n<td>\u2162<\/td>\n<td>Speed\u00a0\u2162<\/td>\n<td>In speed\u00a0\u2162, the pump is set to run on the maximum curve under all operating conditions. Quick venting of the pump can be obtained by setting the pump to speed\u00a0\u2162\u00a0for a short period.<\/td>\n<\/tr>\n<tr>\n<td>\u2161<\/td>\n<td>Speed\u00a0\u2161<\/td>\n<td>In Speed\u00a0\u2161, the pump is set to run on the intermediate curve under all operating conditions.<\/td>\n<\/tr>\n<tr>\n<td>\u2160<\/td>\n<td>Speed\u00a0\u2160<\/td>\n<td>In Speed\u00a0\u2160, the pump is set to run on the min, curve under all operating conditions.<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Night mode<\/td>\n<td>The pump changes to automatic night setback, (the minimum performance and power consumption) provided that certain conditions are met.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Technical Data of ARP Circulation Pump<\/strong><\/p>\n<div class=\"table-responsive\">\n<table class=\"table table-hover ke-zeroborder\">\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>Voltage \/Frequency<br \/>\n(V\/Hz)<\/td>\n<td>Max.Flow<br \/>\n(m3\/h)<\/td>\n<td>Max.Head<br \/>\n(m)<\/td>\n<td>Power<br \/>\n(W)<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>Pipe Size<br \/>\n(inch)<\/td>\n<td>EEI<\/td>\n<td>G.W.<br \/>\n(kg)<\/td>\n<td>Packing Size<br \/>\nEEI (mm)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP15-40\/130<\/td>\n<td>220-240\/50<\/td>\n<td>2<\/td>\n<td>4.1<\/td>\n<td>22<\/td>\n<td>\u03a615<\/td>\n<td>G1\u00d7G1<\/td>\n<td>\u22640.23<\/td>\n<td>2.26<\/td>\n<td>154\u00d7143\u00d7153<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP15-50\/130<\/td>\n<td>220-240\/50<\/td>\n<td>2.3<\/td>\n<td>5.2<\/td>\n<td>32<\/td>\n<td>\u03a615<\/td>\n<td>G1\u00d7G1<\/td>\n<td>\u22640.23<\/td>\n<td>2.26<\/td>\n<td>154\u00d7143\u00d7153<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP15-60\/130<\/td>\n<td>220-240\/50<\/td>\n<td>2.6<\/td>\n<td>6.2<\/td>\n<td>45<\/td>\n<td>\u03a615<\/td>\n<td>G1\u00d7G1<\/td>\n<td>\u22640.23<\/td>\n<td>2.26<\/td>\n<td>154\u00d7143\u00d7153<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP20-40\/130<\/td>\n<td>220-240\/50<\/td>\n<td>2<\/td>\n<td>4<\/td>\n<td>22<\/td>\n<td>\u03a620<\/td>\n<td>G1.25\u00d7G1.25<\/td>\n<td>\u22640.23<\/td>\n<td>2.33<\/td>\n<td>154\u00d7143\u00d7153<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP20-50\/130<\/td>\n<td>220-240\/50<\/td>\n<td>2.3<\/td>\n<td>5.1<\/td>\n<td>32<\/td>\n<td>\u03a620<\/td>\n<td>G1.25\u00d7G1.25<\/td>\n<td>\u22640.23<\/td>\n<td>2.33<\/td>\n<td>154\u00d7143\u00d7153<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP20-60\/130<\/td>\n<td>220-240\/50<\/td>\n<td>2.6<\/td>\n<td>6.1<\/td>\n<td>45<\/td>\n<td>\u03a620<\/td>\n<td>G1.25\u00d7G1.25<\/td>\n<td>\u22640.23<\/td>\n<td>2.33<\/td>\n<td>154\u00d7143\u00d7153<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP25-40\/130<\/td>\n<td>220-240\/50<\/td>\n<td>2.1<\/td>\n<td>4<\/td>\n<td>22<\/td>\n<td>\u03a625<\/td>\n<td>G1.5\u00d7G1.5<\/td>\n<td>\u22640.23<\/td>\n<td>2.39<\/td>\n<td>154\u00d7143\u00d7153<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP25-40\/180<\/td>\n<td>220-240\/50<\/td>\n<td>2<\/td>\n<td>4<\/td>\n<td>22<\/td>\n<td>\u03a625<\/td>\n<td>G1.5\u00d7G1.5<\/td>\n<td>\u22640.23<\/td>\n<td>2.56<\/td>\n<td>198\u00d7143\u00d7160<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP25-50\/130<\/td>\n<td>220-240\/50<\/td>\n<td>2.3<\/td>\n<td>5<\/td>\n<td>32<\/td>\n<td>\u03a625<\/td>\n<td>G1.5\u00d7G1.5<\/td>\n<td>\u22640.23<\/td>\n<td>2.39<\/td>\n<td>154\u00d7143\u00d7153<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP25-50\/180<\/td>\n<td>220-240\/50<\/td>\n<td>2.3<\/td>\n<td>5<\/td>\n<td>32<\/td>\n<td>\u03a625<\/td>\n<td>G1.5\u00d7G1.5<\/td>\n<td>\u22640.23<\/td>\n<td>2.56<\/td>\n<td>198\u00d7143\u00d7160<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP25-60\/130<\/td>\n<td>220-240\/50<\/td>\n<td>2.4<\/td>\n<td>6.1<\/td>\n<td>45<\/td>\n<td>\u03a625<\/td>\n<td>G1.5\u00d7G1.5<\/td>\n<td>\u22640.23<\/td>\n<td>2.39<\/td>\n<td>154\u00d7143\u00d7153<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP25-60\/180<\/td>\n<td>220-240\/50<\/td>\n<td>2.7<\/td>\n<td>6<\/td>\n<td>45<\/td>\n<td>\u03a625<\/td>\n<td>G1.5\u00d7G1.5<\/td>\n<td>\u22640.23<\/td>\n<td>2.56<\/td>\n<td>198\u00d7143\u00d7160<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP32-40\/180<\/td>\n<td>220-240\/50<\/td>\n<td>2.2<\/td>\n<td>4<\/td>\n<td>22<\/td>\n<td>\u03a632<\/td>\n<td>G2\u00d7G2<\/td>\n<td>\u22640.23<\/td>\n<td>2.75<\/td>\n<td>198\u00d7143\u00d7160<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP32-50\/180<\/td>\n<td>220-240\/50<\/td>\n<td>2.5<\/td>\n<td>5.1<\/td>\n<td>32<\/td>\n<td>\u03a632<\/td>\n<td>G2\u00d7G2<\/td>\n<td>\u22640.23<\/td>\n<td>2.75<\/td>\n<td>198\u00d7143\u00d7160<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>ARP32-60\/180<\/td>\n<td>220-240\/50<\/td>\n<td>2.8<\/td>\n<td>6.1<\/td>\n<td>45<\/td>\n<td>\u03a632<\/td>\n<td>G2\u00d7G2<\/td>\n<td>\u22640.23<\/td>\n<td>2.75<\/td>\n<td>198\u00d7143\u00d7160<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>Dimension<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-94625 size-full\" src=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-04.jpg\" alt=\"\" width=\"863\" height=\"513\" srcset=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-04.jpg 863w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-04-300x178.jpg 300w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-04-768x457.jpg 768w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-04-18x12.jpg 18w\" sizes=\"(max-width: 863px) 100vw, 863px\" \/><\/p>\n<p><strong>Materials Table of ARP Circulation Pump<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-94626 size-full\" src=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-05.jpg\" alt=\"\" width=\"473\" height=\"500\" srcset=\"https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-05.jpg 473w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-05-284x300.jpg 284w, https:\/\/bakarna-lda.com\/wp-content\/uploads\/2024\/01\/2-8-2-circulation-pump-05-11x12.jpg 11w\" sizes=\"(max-width: 473px) 100vw, 473px\" \/><\/p>\n<table class=\"table table-hover ke-zeroborder\">\n<tbody>\n<tr>\n<td>No.<\/td>\n<td>Part<\/td>\n<td>Material<\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>Pump body<\/td>\n<td>HT200\/AISI304<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Pump body inset<\/td>\n<td>06Cr19Ni10<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Body gasket<\/td>\n<td>Silicon rubber<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Impeller<\/td>\n<td>PPO<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Locking<\/td>\n<td>06Cr19Ni10<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Check ball<\/td>\n<td>Silicon rubber<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Pump support cover<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Thrust bearing<\/td>\n<td>Graphite<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>Thrust bearing rubber mat<\/td>\n<td>Silicon rubber<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>Thrust bearing adjusting mat<\/td>\n<td>PPO-GF30<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>Rotor<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>Back bearing adjusting mat<\/td>\n<td>PPO-GF30<\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>Can\u00a0brg\u00a0asm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>O-ring<\/td>\n<td>Rubber<\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>Drain plug<\/td>\n<td>DZR<\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>Can\u00a0brg\u00a0asm seal<\/td>\n<td>Silicon rubber<\/td>\n<\/tr>\n<tr>\n<td>17<\/td>\n<td>Motor Stator with winding<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>18<\/td>\n<td>Housing<\/td>\n<td>ADC12<\/td>\n<\/tr>\n<tr>\n<td>19<\/td>\n<td>Screw<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>20<\/td>\n<td>Nameplate<\/td>\n<td>PC<\/td>\n<\/tr>\n<tr>\n<td>21<\/td>\n<td rowspan=\"2\">Cable outlet nut<\/td>\n<td rowspan=\"2\">PA6-GF20<\/td>\n<\/tr>\n<tr>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td>23<\/td>\n<td>Screw<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>24<\/td>\n<td>Tag<\/td>\n<td>PC<\/td>\n<\/tr>\n<tr>\n<td>25<\/td>\n<td>Terminal cover<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>26<\/td>\n<td>Terminal box<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>27<\/td>\n<td>Terminal seal<\/td>\n<td>Rubber<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Application -The ARP circulation pump is used for transferring clean water or other liquids similar to water in physical and chemical properties -Heating systems with constant or variable flows -Heating systems with variable flow-pipe temperature -Heating systems where night setback is desired -Heating systems where the differential pressure of the pump is too high during&hellip;<\/p>\n","protected":false},"featured_media":94621,"comment_status":"open","ping_status":"closed","template":"","meta":{"_eb_attr":""},"product_brand":[],"product_cat":[282,275,273],"product_tag":[],"class_list":{"0":"post-94620","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-circulation-pump","7":"product_cat-commercial-pump","8":"product_cat-pumping","9":"description-off","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product\/94620","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/comments?post=94620"}],"version-history":[{"count":1,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product\/94620\/revisions"}],"predecessor-version":[{"id":94627,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product\/94620\/revisions\/94627"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/media\/94621"}],"wp:attachment":[{"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/media?parent=94620"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=94620"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=94620"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/bakarna-lda.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=94620"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}